Study Of Components And Breakdowns Of Refrigerating Installations
Categories: Technical Educational Equipment
Product Code: AET0091
About this product
Study Of Components And Breakdowns Of Refrigerating Installations
Study Of Components And Breakdowns Of Refrigerating Installations unit is equipped with casters, mounted on a painted and epoxy-treated steel structure, and was designed with an ergonomic design. Study Of Components And Breakdowns Of Refrigerating Installations comprises:- A large printed synoptic panel reproducing the circuits as a whole.
- A refrigerating circuit equipped with a compressor.
- A system to introduce breakdowns, equipped with lights, switches and controls.
- Variable current and voltage circuits.
- A data collection system equipped with corresponding instruments
Teaching objectives
- This unit enables the study and analysis of the following topics.
- Faults on the compressor valve.
- Faults on the oil separator.
- Faults due to excessive coolant.
- Faults due to lack of coolant.
- Total blockage of coolant going to the evaporator.
- Broken regulator.
- Obstructed dehydrator.
- Condensation pressure too high.
- Suction pressure too high.
- Suction pressure too low.
- Electric motor phase cut off.
- Both motor phases cut off.
- Defective refrigerating thermostat.
- Defective freezing thermostat.
- Defective trip coil.
- Defective thermal protection of compressor.
- Defective run capacitor.
- Techniques for mounting/dismounting and connecting the different components.
- Quality control of components.
Technical specifications
- A compressor
- Condenser, fluid indicator, filters, evaporator with thermal load, thermostatic valve, oil separator
- Set of electrical instruments, all class 1.5, comprising: 1 voltmeter, 1 ammeter, 1 wattmeter, 1 COS(Φ) meter, 1 ohmmeter, 1 capacitance meter.
- Flowmeter for coolants.
- Electronic thermometers with PTC sensors.
- Pressure gauges.
- Voltage variator.
- Current variator.
- Fixed voltage cables.
- Complete set of components for running a training programme, comprising thermostats, pressure switches, time delay relays, thermal and capacity protection systems.
- switches for introducing breakdowns in the installation. Breakdowns in the hydraulic part are introduced by activating control valves, while electrical breakdowns are introduced by activating relays.
- Manual of theory and experiments
Services required
- Electricity supply: 230 V - 50 Hz single phase
Dimensions and weight
- 1800 x 800 x 1800 mm – 167 kg
Related Products
Wireless Network Coordinator Trainer
Features of Wireless Network Coordinator Trainer: Wireless Sensor Networking Developmen...
AC Position Control System Using PID
AC Position Control System Using PID Features of AC Position Control System Using PID O...
DC Position Control System Using PID
DC Position Control System Using PID Features of DC Position Control System Using PID 4...
Process Control Simulator
Process Control Simulator Features Built-in Function generator (Sine & Square wave)...
Transfer Function of AC Servo Motor
Transfer Function of AC Servo Motor Atico Export is the best Transfer Function of AC Servo...
Transfer Function of DC Servo Motor
Transfer Function of DC Servo Motor Features of Transfer Function of DC Servo Motor On...
Scada System Heat Transfer Lab
Scada System Heat Transfer Lab Technical Description In Scada System Heat Transfer Lab, th...
Scada System Heat Conduction in Gases and Liquid
Scada System Heat Conduction in Gases and Liquid Technical Description Scada System Heat...